IEC 61753-111-07:2021 纤维光学互连器件和无源元件.性能标准.第111-07部分:密封外壳.A类.天线
标准编号:IEC 61753-111-07:2021
中文名称:纤维光学互连器件和无源元件.性能标准.第111-07部分:密封外壳.A类.天线
英文名称:Fibre optic interconnecting devices and passive components - Performance standard - Part 111-07: Sealed closures - Category A - Aerial
发布日期:2021-09-03
标准范围
IEC 61753-111-07:20 21包含密封光纤封闭件需要满足的最低测试、测试严重性和测量要求,以便被归类为符合IEC 61753表A.13中定义的A类天线的IEC标准?1:2018.本文件不包括自由呼吸关闭。第一版取消并取代了2009年发布的IEC 61753-111-7。本版构成技术修订版。本版本包括以下与IEC 61753相关的重大技术变更?111?7:根据IEC 61753-1:20 18和IEC 61756-1:20 19更新术语和定义;增加了材料抗紫外线和抗真菌测试的详细测试严重性;根据IEC 61753-1:20 18更新测试严重性;密封试验的试验超压改为20 kPa;在机械密封试验中增加了试验过程中压力损失的通过-失败标准;除非另有规定,实验室测试条件符合IEC 61300-1至+23°C±5°C;根据IEC 61756-1:20 19,添加具有储存纤维最小弯曲半径的B-657纤维类型;振动密封试验改为10 Hz,振幅3 mm,循环次数1 000 000次;减少小直径电缆和管道的电缆保持试验中增加的载荷;减少小直径电缆和管道的电缆轴向压缩试验的载荷;增加了扭转和弯曲试验的循环持续时间;删除了自由落体测试(现在包含在光学冲击测试中);组装和拆卸测试的持续时间减少到5个周期;温度变化的持续时间减少到12个循环。
IEC 61753-111-07:2021 contains the minimum tests, test severities and measurement requirements which a sealed fibre optic closure need to meet in order to be categorised as meeting the IEC standard for category A – Aerial, as defined in Table A.13 of IEC 61753?1:2018. Free breathing closures are not covered in this document. This first edition cancels and replaces IEC 61753-111-7 published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753?111?7:
- terms and definitions updated according to IEC 61753-1:2018 and IEC 61756-1:2019;
- detailed test severities added for UV light and fungus resistance tests of materials;
- test severities updated according to IEC 61753-1:2018;
- test overpressure for sealing tests changed to 20 kPa;
- pass-fail criterion of pressure loss during test added to mechanical sealing tests;
- laboratory test conditions harmonized with IEC 61300-1 to +23 °C ± 5 °C, unless otherwise specified;
- addition of B-657 fibre types with minimum bending radius of stored fibres according to IEC 61756-1:2019;
- vibration sealing test changed to 10 Hz, 3 mm amplitude and 1 000 000 cycles;
- reduced loads added in cable retention test for small diameter cables and tubes;
- reduced loads for cable axial compression test for small diameter cables and tubes;
- duration of the cycles in torsion and bending test added;
- free fall test removed (is covered now by the optical shock test);
- duration of the assembly and disassembly test reduced to 5 cycles;
- duration of the change of temperature reduced to 12 cycles.