ISO 8637-1:2024 血液净化用体外系统 第1部分:血液透析器、血液透析滤过器、血液滤过器和血液浓缩器
标准编号:ISO 8637-1:2024
中文名称:血液净化用体外系统 第1部分:血液透析器、血液透析滤过器、血液滤过器和血液浓缩器
英文名称:Extracorporeal systems for blood purification — Part 1: Haemodialysers, haemodiafilters, haemofilters and haemoconcentrators
发布日期:2024-05
标准范围
本文件规定了用于人体的血液透析器、血液透析滤器、血液滤器和血液浓缩器(以下统称为“器械”)的要求和测试方法。本文件不适用于:-体外血液回路;-等离子体过滤器;-血液灌注装置;-血管通路装置;-血泵;-用于制备、维持或监测透析流体的系统;-用于进行血液透析、血液透析滤过、血液滤过或血液浓缩的系统或设备;-后处理程序和设备。注1血液透析器、血液透析滤器和血液滤器的体外血液回路要求见ISO 8637-2。注2血浆过滤器的要求见ISO 8637-3。
This document specifies requirements and test methods for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators, hereinafter collectively referred to as “the device”, for use in humans.
This document does not apply to:
— extracorporeal blood circuits;
— plasmafilters;
— haemoperfusion devices;
— vascular access devices;
— blood pumps;
— systems to prepare, maintain or monitor dialysis fluid;
— systems or equipment intended to perform haemodialysis, haemodiafiltration, haemofiltration or haemoconcentration;
— reprocessing procedures and equipment.
NOTE 1 Requirements for extracorporeal blood circuits for haemodialysers, haemodiafilters and haemofilters are specified in ISO 8637-2.
NOTE 2 Requirements for plasmafilters are specified in ISO 8637-3.