ISO 8600-5:2020 光学和光子学 医用内窥镜和内窥镜治疗设备 第5部分:光学刚性内窥镜光学分辨率的测定
标准编号:ISO 8600-5:2020
中文名称:光学和光子学 医用内窥镜和内窥镜治疗设备 第5部分:光学刚性内窥镜光学分辨率的测定
英文名称:Optics and photonics — Medical endoscopes and endotherapy devices — Part 5: Determination of optical resolution of rigid endoscopes with optics
发布日期:2020-11
标准范围
本文件适用于设计用于医学实践的刚性内窥镜。不包括具有光纤或光电成像系统的内窥镜。它规定了一种测定内窥镜光学分辨率的试验方法。本文件提供了一种测量方法,用于表征刚性内窥镜光学分辨率的三个方面。特征A用于提供内窥镜图像极限分辨率的简单测量。特征B提供低空间频率分辨率的测量,并表征内窥镜图像的清晰度或对比度。特性C提供了内窥镜图像的空间频率响应测量值。
This document applies to rigid endoscopes designed for use in the practice of medicine. Endoscopes having a fibre-optic or opto-electronic imaging system are excluded. It specifies a test method for determining the optical resolution of endoscopes.This document provides a measurement method for characterizing three aspects of the optical resolution of a rigid endoscope. Characteristic A is used to provide a simple measurement of the limiting resolution of the endoscope image. Characteristic B provides a measurement of low spatial frequency resolution and characterizes the sharpness, or contrast, of the endoscope image. Characteristic C provides a measurement of the spatial frequency response of the endoscope image.